220V WATER COOLED SPINDLE MOTOR ER20 2.2KW SPINDLE + 2.2KW DRIVE INVERTER VFD
Price
You save: $30.00! (5.78%)
220V WATER COOLED SPINDLE MOTOR ER20 2.2KW SPINDLE + 2.2KW DRIVE INVERTER VFD
Product Description
Package includes:
1 x Water Pump
1 x 80mm Spindle Clamp
Specifications:
A. 2200W 3HP Water Cooled CNC Milling Spindle KL-2200
- WATER-COOLED ER20 COLLET CHUCK
- Adopt Japanese Imported Bearing
- PASS ISO9001 AND CE QUALITY CERTIFICATION
- Spec: 80*215mm(Middle body diameter 80*215mm)
- Power: 2.2KW
- Voltage: 220 V
- Frequency: 0-400HZ
- Speed: 8000-24000RPM
- ER20 Collet chuck water-cooled
- Runout off: Less than 0.005mm
- Grease lubrication
B. 2.2KW Variable Frequency Drive Inverter
- Input voltage: 220V±5%
- we also stock1.5KW,3KW,4KW,5.5KW,7.5KW inverter, pls contact with us if you need)
- Input Frequency: 48-63HZ
- Output Frequency: 0-400HZ
- Input Phase: Suit for 1 phase input and 3 Phase input.
- Output: 3 Phase
Warranty: One year
Parameter set up for VFD:
PD000=0 for Parameter unlock ( 1 ) for Parameter Lock
PD001=0 (1 For Remote Control)
PD002=0 ( 1 For 0-10v Terminal Control or Remote Trim Pot Control )
( J1 Also Needs to be set for Terminal Control)
PD003=400
PD004=400
PD005=400
PD007=20
PD008=220 (Motor Rated Voltage, If you have 120v spindle then set to 120v )
PD009=15
PD010=8
PD011=120 ( 100 Minimum Setting with Quality VFD, 120 is Safe)
PD13= 08 is for Factory reset, Only use this to set VFD to Factory Default SettingsPD014
Acceleration = 12 ( Adjust to suit)
PD015 Deceleration=12 (Adjust to suit) ( PD15 is ignored IF PD26=1 Then the Spindle will
Coast to a Stop)
PD141=220 ( Motor Rated Voltage ) (120 for VFD Rated for 120v )
PD142= ( Motor Max Amps) PD142=( 220vSet for your motor Amp Rating 2.2Kw Spindle
9 amp )
PD142=( 220VSet for your motor Amp Rating 1.5Kw Spindle 7 amp )
PD142=( 220v Set for your motor Amps Rating 800w Spindle 4 amps )
PD142=( 120v Set for your motor Amp Rating 800w Spindle 7 amp )
PD143=2 ( Motor Number of Poles)
PD144=3000 (Max Motor RPM) =3,000= (24,000)
PD70=0 ( This may need to be set to 1 if Control Voltage is 0-5v )
PD72=400
PD73=120 ( 100 Minimum Setting )
If you have E. Lv. S error code alarm
Pls set
PD200=65535
PD209=70
You can use this tube for the spindle: